products

Masks PM Protective Effect Tester GT-RA10

Masks PM Protective Effect Tester 20+ years R & D sales experience, Perfect after-sales service.

  • Brand:

    GESTER
  • Item NO.:

    GT-RA10
  • Order(MOQ):

    1
  • Product Detail

Masks PM Protective Effect Tester GT-RA10

 

Product Introduction

Application:

Masks PM Protective Effect Tester used for testing the effectiveness of daily protective masks and other types of masks against particulate matter.It is applicable to medical device testing center, safety protection testing center, labor protection testing center, drug testing center, disease prevention and control center, textile testing center, hospital, mask and respirator manufacturing enterprises, etc.

 

Standards:

GB/T 32610


Features
  1. The cold-generated aerosol generator is used to produce continuous and stable aerosol particles, and it is convenient to inject solution.
  2. High precision PM2.5 sensor was used to measure aerosol concentration.
  3. The whole process of particle leakage prevention design to protect the safety of the experimenter.
  4. Aerosol generator 2 sets: salt particulate aerosol generator and oil particulate aerosol generator.
  5. Electrostatic charge neutralization device of aerosol particles is equipped.
  6. Equipped with temperature and humidity sensor, real-time display of ambient temperature and humidity (temperature and humidity requirements: 25℃±5℃, 30%RH±10%RH).
  7. Laser dust particle counter is configured.
  8. High protection test door design, with good sealing, and equipped with operating gloves to facilitate the replacement of the mask to be inspected.
  9. Standard head mold was used for the test of protective effect: 1 standard head mold was used to imitate the real situation of wearing a protective mask.
  10. Protective effect aerosol particles: the concentration range of the test chamber (20-30) mg/m3 can be adjusted, and the concentration fluctuation is less than ±10%;The aerosol generator produced a particle size distribution of 0.02-2 μm, with a median mass diameter of 0.6 μm for salt particles and 0.3 μm for oil particles.
  11. Protective effect aerosol concentration detection device: gas sampling flow (1-2) L/min, sampling frequency: 20 times /min (1-9999 times /min can be set arbitrarily), dynamic detection (0.001-100 times) mg/m3, accuracy 1%.
  12. Protective effect: the sampling tube of inhaled gas is directly under the nose (in the mouth).
  13. The protective effect adopts a breathing simulator to simulate the breathing state of the human body.
  14. Respiratory simulator: sinusoidal airflow, frequency 20 times /min, respiratory flow control (30±1) L/min, respirator flow range: 0-40 L/min.
  15. Instrument accuracy level (accuracy level) : 1
  16. Control system: computer control test process, automatic data collection, special computer and test software configuration.
  17. Computer automatic test and display: medium concentration in the warehouse, medium concentration in the inhaled gas, background concentration;Automatic calculation: protective effect;Can save, output, query, print test data.
  18. Power supply: AC220V 50Hz
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products
Mask Leakage Tester
Protective Mask Leakage Tester GT-RA08B-2
Protective Mask Leakage Tester In stock, fast delivery.
Read More
Medical Face Mask Synthetic Blood Penetration Resistance Tester
Mask Synthetic Blood Penetration Tester GT-RA01
Medical Face Mask Synthetic Blood Penetration Resistance Tester In stock, fast delivery.
Read More
Mask BFE Tester
Mask Bacterial Filtration Efficiency (BFE) Detector GT-RA02B
Mask Bacterial Filtration Efficiency (BFE) Detector In stock, fast delivery.
Read More
Mask Bacterial Filtration Efficiency Tester
Mask Bacterial Filtration Efficiency (BFE) Tester GT-RA02
Mask Bacterial Filtration Efficiency Tester is applied to test the filtration efficiency of mask.
Read More
Mask and Respirator Breathing Resistance Tester
Mask & Respirator Breathing Resistance Tester GT-RA03
Mask and Respirator Breathing Resistance Tester In stock, fast delivery.r
Read More
Face Mask Differential Pressure Tester
Face Mask Differential Pressure Tester GT-RA04
medical face mask differential pressure tester In stock, fast delivery.Professional after-sales team.
Read More
Air-purifying Particle Respiratory Protective Tester
Non-power Air-purifying Particle Respiratory Protective Tester GT-RA05
Non-power Air-purifying Particle Respiratory Protective Tester 20 years R & D sales experience.
Read More
Medical mouth mask flame retardant property tester
Mask Flame Retardant Tester GT-RA06
GESTER Mask Flame Retardant Tester we can provide on-site machine installation and training service.
Read More
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

skype

whatsapp